논문 (학술지)
Dual-Layer Coated Drug-Eluting Stents with Improved Degradation Morphology and Controlled Drug Release
등록번호 | RPMS-2019-0090703362 | SCI 구분
?
※구분 : SCI(SCIE포함), 비SCI |
SCI |
---|---|---|---|
저자명 (주·공동저자) | Bedair Tarek M.; Park Wooram; Park Bang-Ju; Moon Myoung-Woon; Lee Kwang-Ryeol; Joung Yoon Ki; Han Dong Keun | ||
논문구분 | 국내전문학술지 | 학술지명 | MACROMOLECULAR RESEARCH |
ISSN | 1598-5032 | 학술지 출판일자 | 2018-07-01 |
학술지 볼륨번호 | 26 | 논문페이지 | 641 ~ 649 |
학술지 임팩트팩터 | 0.0 | 기여율 | 25 % |
초록 | Drug-eluting stents (DESs) are used to treat cardiovascular diseases such as atherosclerosis. The anti-proliferative drug released from the DES suppress the proliferation of smooth muscle cells and reduced in-stent restenosis. However, a burst release of the drug in the early stages and degradation morphology of the polymer coating represent major disadvantages, which might increase the incidence of in-stent restenosis and/or thrombosis under in vivo clinical studies. To solve these problems, in this study, a double-layer coating system composed of poly(lactide) (PLLA) bottom layer and poly(lactide-co-glycolide) (PLGA) top layer are used for the fabrication of DES. PLLA bottom layer was firstly coated on the metal surface followed by oxygen ion beam treatment. It was found that increasing the ion beam exposure time, increased the roughness of PLLA surface with a nanoscale pocket (or hole)-like structure. The top layer coating represented a mixture of PLGA and paclitaxel (PTX) with 5, 10, and 20% PTX contents. The coating was performed through ultrasonic spray technique, and the morphology showed not only a smooth and uniform surface but also no irregularities were observed at zero day. The drug release and degradation morphology for single-layer (PLGA/PTX) and double-layer (PLLA/PLGA/PTX) coatings were compared. The drug release from the double-layer stainless steel (SS) group showed a slower and controlled drug release for all PTX content samples as compared to single-layer SS group. Moreover, the degradation morphology of double-layer SS group presented a smoother and uniform surface after 12 weeks of degradation under physiological conditions. Therefore, an oxygen ion beam technique with double-layer coating system could effectively control the drug release, i.e., prevent initial burst drug release, and improve the degradation morphology of biodegradable polymer-based DESs. |
연구개발성과 등록 또는 활용에 대한 문의는 논문 연구개발성과 담당자를 통해 문의하시기 바랍니다.
[문의] 한국과학기술정보연구원 Tel : 042)716-7066, https://curation.kisti.re.kr/
- NTIS 관련 이용문의는 NTIS 콜센터(042-869-1115)로 문의하시기 바랍니다.
NTIS의 논문 정보는 국가연구개발사업 수행을 통해 발생된 성과로, 조사분석 등을 통해 입력된 정보를 수집 및 제공하고 있어, 출판사 또는 논문 정보 제공 사이트(Scienceon, RISS 등)에서 일괄 제공하는 논문 정보와 차이가 있을 수 있습니다.