Capacitive biosensor based on vertically paired electrode with controlled parasitic capacitance
등록번호 | RPMS-2019-0190730028 | SCI 구분
?
※구분 : SCI(SCIE포함), 비SCI |
SCI |
---|---|---|---|
저자명 (주·공동저자) | Lee Ga-Yeon; Park Jun-Hee; Chang Young Wook; Kang Min-Jung; Cho Sungbo; Pyun Jae-Chul | ||
논문구분 | 국외전문학술지 | 학술지명 | SENSORS AND ACTUATORS B-CHEMICAL |
ISSN | 0925-4005 | 학술지 출판일자 | 2018-01-01 |
학술지 볼륨번호 | 273 | 논문페이지 | 384 ~ 392 |
학술지 임팩트팩터 | 0.0 | 기여율 | 17 % |
DOI | 10.1016/j.snb.2018.06.050 | ||
초록 | Abstract A capacitive biosensor based on vertically paired electrodes with controlled parasitic capacitance is presented to improve the sensitivity of capacitive measurement. The vertically paired electrodes were fabricated with a parylene film as a dielectric layer, with the distance between the electrodes less than hundreds of nanometer. The problem of parasitic capacitance owing to the electrode configuration was analyzed according to the superposed area of the electrode. In this work, two kinds of vertically paired electrodes were fabricated to control the parasitic capacitance—square-type and circular-type electrodes with different superimposed areas of 21.8 (100%) and 9.3 (42%) mm 2 and the same electrode area of 9.4 × 10 −5 mm 2 , respectively. The effect of superimposed area of the vertically paired electrodes on capacitive measurement was analyzed using the electrodes. The sensitivity of capacitive measurement was observed to increase with a decrease in superimposed electrode area and frequency. Further, the effect of parasitic capacitance was estimated by computer simulation of the sensitivity of impedance and capacitive measurement when 10% change in R S or C S occurred. The results showed that adsorption of proteins could be sensitively measured when the parasitic capacitance decreased. Finally, the effect of superimposed area of the vertically paired electrodes was measured from the interaction between antigens (human serum albumin, HSA) and immobilized antibodies (anti-HSA antibodies). Highlights Two types of vertically paired electrodes with controlled parasitic capacitance was developed. The influence of parasitic capacitance was estimated for capacitive measurement on protein adsorption. Finite element method simulation was used for studying of the influence of parasitic capacitance on the sensitivity of impedance measurement. Immunoassay was presented on two types of vertically paired electrodes with controlled parasit |
연구개발성과 등록 또는 활용에 대한 문의는 논문 연구개발성과 담당자를 통해 문의하시기 바랍니다.
[문의] 한국과학기술정보연구원 Tel : 042)716-7066, https://curation.kisti.re.kr/
- NTIS 관련 이용문의는 NTIS 콜센터(042-869-1115)로 문의하시기 바랍니다.
NTIS의 논문 정보는 국가연구개발사업 수행을 통해 발생된 성과로, 조사분석 등을 통해 입력된 정보를 수집 및 제공하고 있어, 출판사 또는 논문 정보 제공 사이트(Scienceon, RISS 등)에서 일괄 제공하는 논문 정보와 차이가 있을 수 있습니다.